Yes, a two-ply SBS roof can be built without a flame. The base and cap sheets are set in cold adhesive or have a self-adhesive backing, and laps are sealed with adhesive or an electric hot-air welder. The trade-off is temperature: the adhesives need at least 0 C to 4 C and take 48 hours to 7 days to cure.

Quick facts

  • A cold-adhered base sheet is laid in a full bed of adhesive with 100 mm (4 in) side laps, 150 mm (6 in) end laps and end joints staggered 300 mm (12 in).
  • IKO's Cold Gold Field Adhesive is applied at 4 to 40 C (40 to 104 F) and cures in 48 hours under ideal conditions.
  • Soprema's COLPLY EF adhesive has a minimum application temperature of 0 C (32 F) and cures in 7 days at 25 C and 50% relative humidity, longer when colder.
  • Cold Gold Field Adhesive covers 18.6 to 23.2 m2 (200 to 250 ft2) per 18.9 L pail and is not used on slopes over 1:12.
  • On Soprema's COLPLY BASE 410, adhesive goes on the first 100 to 125 mm (4 to 5 in) of each end lap and the last 25 to 50 mm (1 to 2 in) is welded with an electric hot-air welder.
  • IKO's Modiflex MP-180-SS-Base is 2.5 mm (98 mils) and its MP-180-Cap is 3.5 mm (138 mils), about 6.0 mm of membrane together.
  • Where any torch is used, IKO's specification requires a fire watch for 1 hour after each day's roofing stops and an extinguisher within 6 m of each torch applicator.
  • Soprema sorts its flameless sheets into three temperature bands: 10 C or warmer, 0 C or warmer and, with FLEX sheets in SOPRATACK WINTER adhesive, -10 C (14 F) or warmer.

Can a flat roof be installed without a torch?

Yes. The industry specification for cold-applied modified bitumen describes a full roof with no flame: a base sheet set in a full bed of cold adhesive and a cap sheet set the same way.

It names when to choose it: where construction elements or adjoining work can represent fire hazards during use of torch equipment. It also says to specify a self-adhesive base sheet for heat-sensitive substrates.

Three flameless routes exist. In the first, cold adhesive bonds both plies. In the second, both plies are self-adhered: IKO's fully self-adhered option is its ArmourStick HD-Base and ArmourStick HD-Cap, a 4.5 mm peel-and-stick cap sheet.

In the third, a self-adhered base sheet goes down and the cap is still torched, which removes the flame from the deck but not from the roof.

Marku Roofing Repair's low-slope SBS work is torch-applied and self-adhered. Our insured scope of operations is roofing and repair excluding hot tar, so we do not run kettles.

Flashings and penetrations can also go on without a flame. The crew positions a self-adhered base flashing by peeling back 100 to 150 mm (4 to 6 in) of release paper at the top of the parapet, then presses it down, with a reinforcing gusset at every inside and outside corner.

For pipes and odd penetrations, Soprema's SOPRAMASTIC BLOCK system replaces custom metal pans: precast polyester resin blocks are bonded with SOPRAMASTIC SP2, set at least 25 mm (1 in) clear of the penetration, and filled with SOPRAMASTIC PF sealing mastic. The system is solvent-free and odourless.

How does a cold-applied SBS roof work?

The adhesive replaces the hot asphalt or the flame. The crew starts at the drain, works perpendicular to the slope, and lays the base sheet into a full bed of adhesive at the rate the manufacturer specifies, using only the tools it recommends.

Laps are 100 mm (4 in) at the sides and 150 mm (6 in) at the ends, end joints are staggered at least 300 mm (12 in), and corners are cut off at end laps. The crew must seal the base sheet laps at the end of every workday.

The cap sheet follows in another full bed of adhesive. Its side laps are at least 75 mm (3 in) and end laps 150 mm (6 in), staggered at least 300 mm (12 in) from the base sheet joints; under no circumstances may the cap laps sit over the base laps.

The crew rolls the sheet immediately to embed it fully. Soprema recommends installing the cap sheet the same day as the base sheet to keep moisture off the sanded surface.

Sheets made for this have sand on both faces. IKO's Modiflex MP-180-SS-Base is sand-covered top and bottom so it can go on heat-sensitive substrates with mopping asphalt or an IKO-approved cold adhesive. It is 2.5 mm (98 mils) thick, weighs 2,600 g/m2 and meets CSA A123.23 Type B Grade 3.

The Modiflex MP-180-Cap is 3.5 mm (138 mils), 3,700 g/m2, Type B Grade 1, with ceramic-coated granules on top and a sanded underside. Together that is about 6.0 mm and 6.3 kg/m2.

Soprema's COLPLY BASE 410 is a composite-reinforced SBS base sheet sanded on both sides, 2.5 mm minimum, 3.1 kg/m2 (60 lb per 100 ft2), CSA A123.23 Type C Grade 3, with a 100 mm (4 in) selvedge. The roll is set in adhesive spread with a notched squeegee and rolled.

Its laps are where the flame normally comes in, so Soprema seals them differently: adhesive on the first 100 to 125 mm (4 to 5 in) of the end lap, then the last 25 to 50 mm (1 to 2 in) welded with an electric hot-air welder and a roller, and every side lap welded too.

Upstands use a heavier adhesive and narrower strips. Cap sheet flashing goes on in strips no wider than 1 m, with 100 mm (4 in) side laps staggered at least 100 mm from the field cap joints, overlapping the field 50 mm (2 in) more than the base flashing does.

A chalk line 150 mm (6 in) from the upstand marks the edge. For a self-adhered cap flashing, adhesive goes on the first 125 mm (5 in) of the lap with the field and the last 25 mm (1 in) is heat-welded with an electric hot-air gun.

What temperature does roofing adhesive need?

Every cold adhesive has a floor, and in a Calgary winter that floor decides the schedule. The two manufacturers publish these limits:

Property IKO Cold Gold Field Adhesive IKO Cold Gold Flashing Adhesive Soprema COLPLY EF Soprema COLPLY EF FLASHING CEMENT
Chemistry Solvent-free, single-component, cold-applied interply adhesive Single-component, asphalt-modified urethane, solvent-free Odourless polyether-based adhesive Odourless polyether-based adhesive
Where used Field of the roof; not on vertical surfaces or a pitch over 1:12 Steep and vertical surfaces Low slopes under 3% (3/8 in per ft) Flashings and slopes over 3%
Application temperature 4 to 40 C (40 to 104 F) 4 to 40 C (40 to 104 F) 0 C (32 F) minimum 0 C (32 F) minimum
Cure time 48 hours under ideal conditions 48 hours under ideal conditions; drying slower when colder 7 days at 25 C and 50% RH; longer when colder 7 days at 25 C and 50% RH; longer when colder
Spreading tool 1/4 in (6.4 mm) V-notched trowel or squeegee V-notched for smooth surfaces, square-notched for rough 4.8 mm (3/16 in) or 6.0 mm (1/4 in) notched squeegee 4.8 mm or 6.0 mm notched trowel
Coverage 18.6 to 23.2 m2 (200 to 250 ft2) per 18.9 L pail 18.6 to 23.2 m2 (V-notch) or 9.3 to 11.6 m2 (square-notch) per pail 0.8 to 1.2 L/m2 on sanded surfaces; 1.2 to 1.6 L/m2 on granules 0.8 to 1.2 L/m2 on sanded surfaces; 1.2 to 1.6 L/m2 on granules
VOC Under 250 g/L Under 250 g/L 31 g/L 15 g/L
Storage 15 to 27 C (60 to 80 F) just before use 15 to 27 C (60 to 80 F) just before use 5 to 40 C (41 to 104 F) 5 to 40 C (41 to 104 F)
Shelf life 9 months 9 months 9 months 6 months

Two more rules matter. COLPLY EF must not be used with ELASTOCOL 500 primer. Soprema also recommends its COLPLY BASE 410 FLEX version when the base sheet is installed with cold adhesive below 0 C (32 F).

Cold Gold Field Adhesive doubles as a cold-applied flood coat with approved stone, covering 9.29 to 13.94 m2 (100 to 150 ft2) per pail.

Soprema sorts its flameless range for exposed, granule-surfaced roofs into three temperature bands, which shows what a crew can still install as the weather cools:

Application temperature Base sheet options Cap sheet options
10 C (50 F) or warmer COLVENT BASE 840 or SOPRAPLY STICK DUO, self-adhesive; 2-1 SOPRASMART BOARD SANDED or 2-1 SOPRASMART ISO HD SANDED, set in DUOTACK adhesive or mechanically fastened SOPRAPLY STICK TRAFFIC CAP or SOPRASTAR STICK GR, self-adhesive; both also come in FR versions
0 C (32 F) or warmer COLPLY BASE 410 in SOPRATACK or COLPLY EF adhesive; SOPRAPLY STICK DUO, self-adhesive; either 2-1 board COLPLY TRAFFIC CAP in SOPRATACK or COLPLY EF adhesive; SOPRAPLY STICK TRAFFIC CAP, self-adhesive
-10 C (14 F) or warmer COLPLY BASE 410 FLEX in SOPRATACK WINTER adhesive; either 2-1 board COLPLY TRAFFIC CAP FLEX in SOPRATACK WINTER adhesive

Soprema states that the two 2-1 panels can be installed all year long without any temperature limitation, which is why they appear in every band. SOPRATACK is a two-component polyurethane adhesive that Soprema lists as fully cured in 24 hours, against seven days for COLPLY EF, and its WINTER version is the one rated down to -10 C (14 F).

Soprema's bitumen-based COLPLY adhesive, for slopes under 3%, has the same 0 C (32 F) minimum and the same coverage rates as COLPLY EF, but takes 30 days to cure fully at 25 C and 50% relative humidity. It keeps for up to 18 months in sealed containers.

Temperature sets the calendar for a flameless roof, because every adhesive has a floor and a cure, counted in days, that lengthens in the cold. Strength is a separate matter, taken up next.

Is a self-adhered flat roof as strong as torch-on?

The sheet sets the strength, and the same product grades appear on both sides. CSA A123.23 classes membranes by type and grade. IKO's self-adhering ArmourStick HD-Cap is Type C Grade 1, the same class as its heat-welded Torchflex TP-HD-Cap.

The adhesive-applied Modiflex MP-180-Cap is Type B Grade 1, the same as the torched Torchflex TP-250-Cap. MP-180-Cap reports a peak load above 9.5 kN/m at 23 C and above 12.3 kN/m at -18 C, low-temperature flexibility below -18 C and granule loss under 2 g.

Wind resistance is tested as a whole assembly, and adhered assemblies have published results. IKO's AARS030-B, tested by EXP Services under CSA A123.21, uses a self-adhesive vapour barrier on a steel deck, two layers of 1 1/2 in polyisocyanurate and a 1/2 in ShieldBase 180 cover board with a factory-laminated SBS base sheet, all glued with Millennium Adhesive in ribbons 12 in on centre.

It reached a dynamic uplift resistance of -3.4 kPa (-71 psf) under the 2020 edition of the standard. Soprema's assembly over a plywood deck at least 5/8 in thick, a 2-1 SOPRASMART ISO HD laminated panel in DUOTACK adhesive, reached -3.9 kPa (-82 psf) with ribbons at 12 in and -6.2 kPa (-130 psf) with ribbons at 6 in.

The adhesive pattern is engineered, not improvised. IKO's specification requires shop drawings showing the adhesive pattern for the field, perimeter zone and corner zone, set to CSA A123.21. Bead layout matters less than spacing: the test lab notes that S-shaped or straight beads do not change the result.

When is torching still used on a torch-free roof?

Often, a torch still appears somewhere, so ask your contractor which parts are flameless. Both laminated-panel assemblies above use a heat-welded cap sheet: the flame meets the factory-laminated panel, not the deck or the insulation.

IKO's specification lists a system with a self-adhered base and a torched cap, and it torch-applies walkways after priming the cap sheet. IKO also notes that Modiflex and Torchflex roofs can be repaired with a hand torch and a round-nosed trowel.

Hot-air welding is not torching. The electric hot-air welder that seals COLPLY laps and the last 25 mm of self-adhered flashings uses heated air, not a flame, which is why it appears in flameless specifications.

Where a crew uses a torch, the safety rules apply. IKO's specification requires an ABC fire extinguisher on the roof within 6 m of each torch applicator and a fire watch for 1 hour after each day's roofing stops.

The industry specification requires a self-adhesive fire stop membrane before any torch-applied vapour barrier at cracks, voids, angle changes at curbs and parapets, penetrations and anywhere a back draft could draw flame into combustible materials. Working with a torch on a roof is a job for trained crews only.

Choosing a torch-free assembly

Start from the deck and the season. Over a wood deck or combustible parapet, the specification points to a self-adhesive base sheet; IKO also offers a cover board with a factory-laminated base sheet, and Soprema a laminated 2-1 panel.

An asphalt core board can serve as a protection board under torchable, self-adhered or cold-applied membranes. On a fully cold-adhered roof, plan the work for days at or above 4 C for Cold Gold or 0 C for COLPLY EF, and keep traffic off until the adhesive cures.

Check the installer and the warranty paperwork. IKO's specification asks for an applicator with at least five years of documented experience who is an IKO registered applicator, and offers 10, 15 or 20 year warranties.

Add both to your questions to ask a roofing contractor before hiring. The deck must be dry and free of snow, ice and frost, and calcium or salt must not be used to clear it. Sealants are stored at 5 C or warmer.

Torch-free and hybrid products named on a quote

The product names on a quote tell you which layers are adhered and which still need heat. The table lists IKO and Soprema sheets and boards that appear on torch-free and hybrid SBS quotes, as their makers describe them.

Product What it is Reinforcement and CSA A123.23 class Thickness Size How it goes on
IKO Modiflex MP-HD-Cap Granule-surfaced cap sheet Polyester with glass fibre scrim; Type C, Grade 1 3.5 mm (138 mils) 10 m by 1,005 mm roll Sanded underside set in mopping asphalt or an IKO-approved cold adhesive
IKO Modiflex MP-250-Cap Granule-surfaced cap sheet Polyester with glass fibre strands; Type B, Grade 1 3.8 mm (150 mils) 10 m by 1,005 mm roll Sanded underside set in mopping asphalt or an IKO-approved cold adhesive
IKO PrevENt MP-250-Cap Fire-resistant cap sheet with expandable graphite above the reinforcement Polyester with glass fibre strands; Type B, Grade 1 3.8 mm (150 mils) 10 m by 1,005 mm roll; covers 9.10 m2 (98 ft2) Sanded underside set in mopping asphalt or an IKO-approved cold adhesive
IKO ArmourStick HD-Cap Peel-and-stick cap sheet Composite mat with glass fibre strands; Type C, Grade 1 4.5 mm (177 mils) 8 m by 1,005 mm roll; covers 7.25 m2 (78 ft2) Self-adhered at 5 C (41 F) or warmer, with no primer over ArmourStick HD-Base; last 2 in of the selvage hot-air welded
IKO Fast-N-Stick HD-Base Base sheet with a self-adhering 102 mm (4.0 in) selvage Polyester with glass fibre scrim; Type C, Grade 3 2.5 mm (98 mils) 15 m by 1,005 mm roll; covers 13.47 m2 (145 ft2) Mechanically fastened; film top for a heat-welded cap sheet
IKO ShieldBase 180 Polyiso cover board with a factory-laminated base sheet and an R-value of 2.5 Polyester; Type B, Grade 3 12.7 mm (0.50 in) board plus 2.2 mm (87 mils) membrane 2.44 m by 0.914 m (8 ft by 3 ft) board Fastened at 18 in on centre, glued with Millennium Adhesive or set in hot asphalt; film or sand top
IKO Protectobase 180 Asphalt core board with a factory-laminated base sheet Polyester with glass fibre strands; Type B, Grade 3 7.0 mm in total, 2.2 mm (87 mils) of it membrane 2.4 m by 915 mm (8 ft by 36 in) board Attachment not stated; film top for a heat-fused cap sheet, sand top for mopping or cold adhesive
Soprema SOPRALAP STICK Self-adhesive cover strip for the end laps of laminated panels and COLVENT base sheets Composite; Type C, Grade 3 2.5 mm (98 mils) 12 m by 0.33 m (13 in) roll Peeled and rolled onto a primed surface at 0 C (32 F) or warmer
IKO ArmourCool Granular TP-HD-Cap White reflective cap sheet with a solar reflective index of 82 or more Polyester with glass fibre scrim; Type C, Grade 1 5.0 mm (197 mils) 8 m by 1,005 mm roll; covers 7.25 m2 (78 ft2) Heat-welded with a torch

The letters in IKO's names matter. The MP sheets above have a sanded underside for asphalt or cold adhesive, while the TP sheet has a film underside that disappears under the torch, so a TP cap sheet on a quote means the cap is heat-welded.

The two boards come with either a film top, for a torched cap, or a sand top, for a mopped or cold-adhered cap, so check that the version of the board matches the cap sheet on the quote.

Both boards have self-adhering selvages that join each one to the next, and IKO describes ShieldBase 180 as a good choice for re-cover work because it reduces the dead load of the roofing system.

Fire rating is a separate line to check. IKO states that PrevENt MP-250-Cap qualifies for a Class A rating in select UL systems under CAN/ULC S107M and UL 790.

Under its Factory Mutual approvals, IKO lists the standard ArmourCool cap as Class C to a 1/2:12 slope limit and the PrevENt version as Class A to a 1-1/2:12 slope limit.

IKO wants ArmourStick HD-Cap rolls stored upright and indoors in their unopened packaging, and kept out of direct sunlight and extreme cold or heat if they are stored outside.

What this means for a Calgary roof

On a Calgary infill, row house or wood-frame building with combustible parapets, a cold-adhered or self-adhered SBS roof keeps the flame off the wood.

The limit is weather: Calgary winter temperatures regularly fall below -20 C, well under the 0 C and 4 C adhesive minimums, and cure times of 48 hours to 7 days get longer as it cools, so fully flameless work belongs in the warmer months.

A chinook warm spell can open a short window, but cure time still has to fit inside it. Marku Roofing Repair can assess your deck and parapets and quote a torch-free or hybrid SBS roof; call 403-700-7542.

Questions people ask

Is torch-on roofing safe?

It is done safely under strict rules: a fire stop membrane at openings, no flame directly on combustible surfaces, an extinguisher within 6 m of each torch and a 1 hour fire watch after work stops. Where those risks are hard to control, the specification itself points to cold-applied or self-adhered sheets.

What temperature does roofing adhesive need?

IKO's Cold Gold adhesives need 4 to 40 C and Soprema's COLPLY EF adhesives need at least 0 C. Storage temperatures before use are 15 to 27 C for Cold Gold and 5 to 40 C for COLPLY EF.

How long does cold adhesive take to cure?

Cold Gold cures in about 48 hours under ideal conditions. COLPLY EF and EF FLASHING CEMENT take about 7 days at 25 C and 50% humidity, and longer in cooler weather or with heavier application.

Is a self-adhered flat roof as strong as torch-on?

The membrane classes are the same: IKO's self-adhered ArmourStick HD-Cap and its torched TP-HD-Cap are both CSA A123.23 Type C Grade 1. Tested adhered assemblies reach dynamic uplift resistances of -3.4 to -6.2 kPa depending on the adhesive spacing.

Can a flat roof be installed without a torch?

Yes, with cold-adhered or self-adhered base and cap sheets, laps sealed by adhesive or electric hot-air welding, and flameless details such as SOPRAMASTIC BLOCK at penetrations.

When is torching still used on a torch-free roof?

Most often for the cap sheet over a self-adhered or laminated base, for torch-applied walkways and for repairs. Ask your contractor which layers are torched and which are adhered.

Free written estimate

Have Kristjan look at it properly

Reading about it only goes so far. He gets on the roof, photographs what he finds, and hands you a scope with a number on it. If a repair is the right answer, he says so.

Call KristjanHave Kristjan look at it

Kristjan does the estimates himself. Free, written, and not a range.

Reviews

What Calgary says about the work

5.0from 100 Google reviews

Read all 100 on Google

Reviews are published on our Google Business Profile and shown here as written.Check them yourself.

Call KristjanFree estimate